docs: add plugin feedback for Android rollover-interval bugs (since fixed)

Document two rollover-interval bugs for daily-notification-plugin with
logcat evidence and required fixes. Both issues have been fixed on the
plugin side; rollovers now chain every N minutes across reboots without
opening the app.
This commit is contained in:
Jose Olarte III
2026-03-04 22:27:08 +08:00
parent af63ab70e7
commit 6825bd5214
3 changed files with 108 additions and 4 deletions

View File

@@ -0,0 +1,104 @@
# Plugin feedback: Android rollover interval two bugs (logcat evidence)
**Date:** 2026-03-04
**Target:** daily-notification-plugin (Android)
**Feature:** `rolloverIntervalMinutes` (e.g. 10 minutes for testing)
**Result:** Two bugs prevent rollover notifications from firing every 10 minutes when the user does not open the app.
---
## Test setup
- Schedule set with **rolloverIntervalMinutes=10** (e.g. first run 20:05).
- Expected: notification at 20:05, 20:15, 20:25, 20:35, 20:40 (after user edit), 20:50, 21:00, 21:10, 21:20, …
- User did **not** open the app between 20:25 and 20:36, or between 21:10 and 21:20.
---
## Bug 1: Rollover interval not applied when the firing run is a rollover schedule
### Observed
- **20:25** Notification fired (room content; work id UUID, scheduleId `daily_rollover_1772540701872`).
- **20:35** **No notification.**
### Logcat evidence (20:25 fire)
There is **no** `DN|ROLLOVER_INTERVAL` or `DN|ROLLOVER_NEXT using_interval_minutes=10` in this block. Next run is set to **next day** at 20:25, not today 20:35:
```
03-03 20:25:01.844 D/DailyNotificationWorker: DN|RESCHEDULE_START id=29e1e984-d8b2-49ea-bb69-68b923fe4428
03-03 20:25:01.874 D/DailyNotificationWorker: DN|ROLLOVER next=1772627100000 scheduleId=daily_rollover_1772540701872 static=false
03-03 20:25:01.928 I/DNP-SCHEDULE: Scheduling next daily alarm: id=daily_rollover_1772540701872, nextRun=2026-03-04 20:25:00, source=ROLLOVER_ON_FIRE
```
Compare with a fire that **does** use the interval (e.g. 20:15):
```
03-03 20:15:01.860 D/DailyNotificationWorker: DN|ROLLOVER_INTERVAL scheduleId=daily_timesafari_reminder minutes=10
03-03 20:15:01.862 D/DailyNotificationWorker: DN|ROLLOVER_NEXT using_interval_minutes=10 next=1772540700870
03-03 20:15:01.870 D/DailyNotificationWorker: DN|ROLLOVER next=1772540700870 scheduleId=daily_timesafari_reminder static=false
```
### Root cause
When the notification that just fired was scheduled from a **previous** rollover (i.e. work id is UUID / scheduleId is `daily_rollover_*`), the rollover path appears to use **+24 hours** and never reads or applies the stored `rolloverIntervalMinutes`. The interval is only applied when the firing schedule is the main/canonical one (e.g. `daily_timesafari_reminder`).
### Required fix
When scheduling the next run after a notification fires (rollover path), **always** resolve the **logical** schedule (e.g. map `daily_rollover_*` back to the main schedule id) and read the stored `rolloverIntervalMinutes` for that reminder. If present and > 0, set next trigger = current trigger + that many minutes (using the same logic as the path that already logs `ROLLOVER_INTERVAL` / `ROLLOVER_NEXT`). Only use +24 hours when the interval is absent or 0.
---
## Bug 2: ROLLOVER_ON_FIRE reschedule skipped as “duplicate” so next alarm is never set
### Observed
- **21:10** Notification fired; worker correctly computes next = 21:20 (epoch 1772544000862).
- **21:20** **No notification.**
### Logcat evidence (21:10 fire)
Worker applies interval and requests next at 21:20; schedule layer skips and does **not** set the alarm:
```
03-03 21:10:01.281 D/DailyNotificationWorker: DN|ROLLOVER_INTERVAL scheduleId=daily_timesafari_reminder minutes=10
03-03 21:10:01.284 D/DailyNotificationWorker: DN|ROLLOVER_NEXT using_interval_minutes=10 next=1772544000862
03-03 21:10:01.294 D/DailyNotificationWorker: DN|ROLLOVER next=1772544000862 scheduleId=daily_timesafari_reminder static=false
03-03 21:10:01.313 W/DNP-SCHEDULE: Skipping duplicate schedule: id=daily_timesafari_reminder, nextRun=2026-03-03 21:20:00, source=ROLLOVER_ON_FIRE
03-03 21:10:01.314 W/DNP-SCHEDULE: Existing PendingIntent found for requestCode=53438 - alarm already scheduled
03-03 21:10:01.332 I/DailyNotificationWorker: DN|RESCHEDULE_OK ...
```
So the worker reports RESCHEDULE_OK, but the scheduler did **not** call through to set the OS alarm for 21:20. The “existing” PendingIntent was for the alarm that **just fired** (21:10). Idempotence is preventing the **update** to the new trigger time.
### Root cause
Duplicate/idempotence logic (e.g. “Existing PendingIntent found for requestCode=53438”) is applied in a way that skips scheduling when the same schedule id is used with a **new** trigger time. For `source=ROLLOVER_ON_FIRE`, the same schedule id is **supposed** to be updated to a new trigger time every time a rollover fires. Skipping when only the trigger time changes breaks the rollover chain.
### Required fix
For `source=ROLLOVER_ON_FIRE`, do **not** skip scheduling when the only “match” is the same schedule id with a **different** `nextRun`/trigger time. Either:
- Treat “same schedule id, different trigger time” as an **update**: cancel the existing alarm (or PendingIntent) for that schedule and set the new one for the new trigger time, or
- In the idempotence check, require that the **existing** alarms trigger time equals the **requested** trigger time before skipping; if the requested time is different, proceed with cancel + set.
After the fix, when the 21:10 alarm fires and the worker requests next at 21:20, the schedule layer should cancel the 21:10 alarm and set a new alarm for 21:20 (same schedule id, new trigger).
---
## Desired behavior (for reference)
Once both bugs are fixed:
- Rollover notifications should keep being scheduled every `rolloverIntervalMinutes` (e.g. 10 minutes) **without the user opening the app** between fires.
- Flow: alarm fires → Receiver → Worker (display + reschedule) → schedule layer sets next alarm. All of this runs when the alarm fires; no app launch required.
---
## Summary table
| Time | Expected | Actual | Bug |
|--------|------------------------|---------------|-----|
| 20:35 | Rollover notification | No notification | **Bug 1:** Rollover from `daily_rollover_*` path uses +24h instead of `rolloverIntervalMinutes`. |
| 21:20 | Rollover notification | No notification | **Bug 2:** Schedule layer skips with “Skipping duplicate schedule” / “Existing PendingIntent found”; 21:20 alarm never set. |

6
package-lock.json generated
View File

@@ -38,7 +38,7 @@
"@pvermeer/dexie-encrypted-addon": "^3.0.0",
"@simplewebauthn/browser": "^10.0.0",
"@simplewebauthn/server": "^10.0.0",
"@timesafari/daily-notification-plugin": "git+https://gitea.anomalistdesign.com/trent_larson/daily-notification-plugin.git#rollover-interval",
"@timesafari/daily-notification-plugin": "git+https://gitea.anomalistdesign.com/trent_larson/daily-notification-plugin.git#master",
"@tweenjs/tween.js": "^21.1.1",
"@types/qrcode": "^1.5.5",
"@veramo/core": "^5.6.0",
@@ -8651,8 +8651,8 @@
}
},
"node_modules/@timesafari/daily-notification-plugin": {
"version": "1.3.0",
"resolved": "git+https://gitea.anomalistdesign.com/trent_larson/daily-notification-plugin.git#27144800706094d292115737de3095a7959e8090",
"version": "1.3.1",
"resolved": "git+https://gitea.anomalistdesign.com/trent_larson/daily-notification-plugin.git#6f4d9466622d9cb35e40ecedb5da9831920701aa",
"license": "MIT",
"workspaces": [
"packages/*"

View File

@@ -151,7 +151,7 @@
"@capacitor/share": "^6.0.3",
"@capacitor/status-bar": "^6.0.2",
"@capawesome/capacitor-file-picker": "^6.2.0",
"@timesafari/daily-notification-plugin": "git+https://gitea.anomalistdesign.com/trent_larson/daily-notification-plugin.git#rollover-interval",
"@timesafari/daily-notification-plugin": "git+https://gitea.anomalistdesign.com/trent_larson/daily-notification-plugin.git#master",
"@dicebear/collection": "^5.4.1",
"@dicebear/core": "^5.4.1",
"@ethersproject/hdnode": "^5.7.0",