You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
21 lines
4.7 KiB
21 lines
4.7 KiB
id&qtp&qim&qil&qtx&qca&qia&qrm&qnxt&qprv&qalb&subj&wght&pts&flr&ded&layout&qfixed&qptsbyans&flags
|
|
DIQTest1.001&mcs&0&N&RAMVACs have:&Controls and Motors that are not waterproof&Motors that are waterproof but controls that are not;Controls that are waterproof but motors that are not;Motors than can be converted from 3 phase to single phase;Motors than can be converted from single phase to 3 phase;&&&&A&Install.0&&&&&1:v&&&N.
|
|
DIQTest1.002&mcs&0&N&RAMVAC exhausts must avoid using:&Tar coated pipe&DWV fittings ;Loose supports;Metal pipe;PVC pipe;&&&&A&Install.0&&&&&1:v&&&N.
|
|
DIQTest1.003&mcs&0&N&The maximum current draw for a 230v Bulldog QT 2 is:&6.7 amps &13.4 amps;20 amps;13.4 or 6.7 amps;The same as 115v systems;&&&&A&Install.0&&&&&1:v&&&N.
|
|
DIQTest1.004&mcs&0&N&Unless specifically ordered differently, a Bison 3 must run on:&1 phase, 230v power&3 phase, 230v power;3 phase, 460v power;60 Hz or 50 Hz power;1 phase, 460v power;&&&&A&Install.0&&&&&1:v&&&N.
|
|
DIQTest1.005&mcs&0&N&The final step in a proper installation is to:&Complete the Installation Checklist&Complete checking the drip rate;Make sure the motor amperage is correct ;Test run the RAMVAC;Make sure the exhaust is terminated correctly;&&&&A&Install.0&&&&&1:v&&&N.
|
|
DIQTest1.006&mcs&0&N&RAMVAC air filters are all of the following except:&In plain sight&Located both inside and outside the Filtrols ;Accessed without tools;Washable and reusable;An important part of routine maintenance;&&&&A&User_Guide.0&&&&&1:v&&&N.
|
|
DIQTest1.007&mcs&0&N&RAMVAC expects Bulldog v-belts to typically last:&20 years&10 years;Until they begin to squeak;Not as long as Bison v-belts;Indefinitely;&&&&A&User_Guide.0&&&&&1:v&&&N.
|
|
DIQTest1.008&mcs&0&N&Expect the drip rate to normally be:&1 to 3 drips per minute at each dripper&1 to 3 drips per second at each dripper;1 to 3 drips per minute total;Enough to keep the pump from squeaking at start-up;6 drips per minute total;&&&&A&User_Guide.0&&&&&1:v&&&N.
|
|
DIQTest1.009&mcs&0&N&Filtrols Moisture Faults are:&Not normal&Eventually going to happen to everyone;Can be bypassed and ignored;Caused by exceeding �Normal� use ;The same for all brands of vacuum systems;&&&&A&User_Guide.0&&&&&1:v&&&N.
|
|
DIQTest1.010&mcs&0&N&A flashing remote light indicates:&Response is required&The RAMVAC will not run;The RAMVAC will run;You must cycle the remote switch ;The warranty is void;&&&&A&User_Guide.0&&&&&1:v&&&N.
|
|
DIQTest1.011&mcs&0&N&First and foremost, vacuum must:&Satisfy the user&Meet RAMVAC standards;Provide at least 8 SCFM per HVE;Provide at least 10 SCFM per HVE;Pass the Vacheck Test;&&&&A&Technical.0&&&&&1:v&&&N.
|
|
DIQTest1.012&mcs&0&N&Vacuum piping is important for all of the following except:&It must match the type of pump&It affects vacuum system performance; It affects reliability;It affect how many people a system can serve;It must remain clog free;&&&&A&Technical.0&&&&&1:v&&&N.
|
|
DIQTest1.013&mcs&0&N&Flow is measured in units of SCFM, which stands for:&Standard Cubic Feet per Minute&Safe Cubic Feet per Minute;Standard Cubic Foot-Meter ;Sea-level Cubic Feet per Minute ;Sea-level Cubic Foot-Meter;&&&&A&Technical.0&&&&&1:v&&&N.
|
|
DIQTest1.014&mcs&0&N&RAMVAC�s vacuum controller:&Should be adjusted only with all vacuum devices closed &Should not be adjusted;Can be used to increase full flow vacuum strength;Can be used to increase the number of vacuum devices served ;Should be adjusted only with all vacuum devices open;&&&&A&Technical.0&&&&&1:v&&&N.
|
|
DIQTest1.015&mcs&0&N&All materials removed from the treatment room contacts the:&Separating tank&Pump;Vacuum controller filter;Moisture Fault system;Main air filter;&&&&A&Technical.0&&&&&1:v&&&N.
|
|
DIQTest1.016&mcs&0&N&Select the best RAMVAC Systems by:&Knowing how many HVEs or the equivalent need to be served&Matching the Power unit to the number of rooms;Knowing how many users need to be served;Counting saliva ejectors as half of a HVE;Matching the Power Unit to the number of users;&&&&A&Catalog.0&&&&&1:v&&&N.
|
|
DIQTest1.017&mcs&0&N&3 HVEs, 5 saliva ejectors, and 2 nitrous oxide scavengers equals:&4.5 HVE Equivalents&10 HVE Equivalents;6 HVE Equivalents;6.5 HVE Equivalents;4.2 HVE Equivalents;&&&&A&Catalog.0&&&&&1:v&&&N.
|
|
DIQTest1.018&mcs&0&N&Bulldogs are available for:&115v or 230v, single phase power&230v, single phase power;115v or 230v, single or three phase power;60 Hz power only ;60 HZ power if special ordered;&&&&A&Catalog.0&&&&&1:v&&&N.
|
|
DIQTest1.019&mcs&0&N&Unless specifically ordered otherwise, a Bison 3 will set-up to run on:&Single phase power&230v three phase power;Three phase power;115v or 230v power;230v or 460v power;&&&&A&Catalog.0&&&&&1:v&&&N.
|
|
DIQTest1.020&mcs&0&N&A Bison 9 must always be run on:&Three phase power&Single phase power;230v three phase power;460v three phase power;230v single phase power;&&&&A&Catalog.0&&&&&1:v&&&N.
|
|
|